X-RAY TELEVISION SYSTEMS “FILIN”

X-ray television systems transform X-rays into the visible image. The image is being generated on the display of computer system, designed for filing and improving X-ray images “SOVA+”. The image is being directly generated in real time making the control process quick and convenient. The function of the image enlargement allows the examination of the object with higher resolution. The application of the system together with mechanical manipulators, conveyers, rolling tables ensures the on-line examination of practically any products in arbitrary positions.

Below you could find the list of commercially available systems of the series FILIN with their brief technical characteristics. To get more detailed information about any specific unit push button “Details” in the system description. To order the unit push button “Order”.

General information about X-ray television systems of series FILIN, based on X-ray electro optical image amplifier).

General information about X-ray television systems of series FILIN, based on X-ray flat panel semi-conductor detector.

Before the selection of the unit, it is recommended to read the article "Criteria for the selection of X-ray television systems".

You can also select the self-contained complex of FILIN series for the complex solution of the tasks of radioscopic inspection. To do this, switch to the section “X-ray television complexes"

The weight of the systems based on flat panel detectors is indicated for the limiting voltage of 225kV. When ordering the detector designed for other limiting voltage (higher or lower) the weight of detector would be respectively bigger or smaller. 

  ФИЛИН 3232
 

FILIN 3232

To change X-ray films in stationary conditions.

Effective size of entrance window: 320 x 320 mm
Number of image elements: 3650 x 3650
Size of image element: 83 micron
Visual resolution on display: not less than 12 line/mm
Energy range: 10 … 225 kV
Dynamic range: > 4000:1
Weight of detector: 11.4 kg


  ФИЛИН 4747
 

FILIN 4747

To change X-ray films in stationary conditions.

Effective size of entrance window: 470 x 470 mm
Number of image elements: 5500 x 5500
Size of image element: 83 micron
Visual resolution on display: not less than 12 line/mm
Energy range: 10 … 225 kV
Dynamic range: > 4000:1
Weight of detector: 15.9 kg


  Оптика с переменным фокусным расстоянием для рентгенотелевизоров на основе РЭОПа
 

Optics with variable focal length for X-ray TV sets based on X-ray electro optics

Optics with variable focal length for X-ray TV sets based on X-ray electro optics


  Автоматизированные независимые шторки до 225кВ
 

Automated independent shutter of up to 225 kV

Designed for the protection of X-ray TV set with entrance window of up to 215mm against direct unshielded radiation with energy of up to 225 kV.


  Автоматизированные независимые шторки до 450кВ
 

Automated independent shutter of up to 450kV

Designed for the protection of X-ray TV set with entrance window of up to 215mm against direct unshielded radiation with energy of up to 450 kV.


  Автоматизированная диафрагма излучения до 225 кВ
 

Automated radiation diaphragm of up to 225 kV

It is designed for the confinement of the beam with radiation energy of up to 225 kV. Increases the quality of X-ray television examination.


  Автоматизированная заслонка излучения до 225 кВ
 

Automated shutter against radiation of up to 225 kV

It is designed to intercept the X-ray beam with radiation energy of up to 220 kV during the change of the product. It excludes any need in switching off the X-ray unit during the quick change of the products.


  Автоматизированная диафрагма излучения до 450 кВ
 

Automated radiation diaphragm of up to 450 kV

It is designed for the confinement of the beam with radiation energy of up to 450 kV. Increases the quality of X-ray television examination.


  Автоматизированная заслонка излучения до 450 кВ
 

Automated shutter against radiation of up to 450 kV

It is designed to intercept the X-ray beam with radiation energy of up to 450 kV during the change of the product. It excludes any need in switching off the X-ray unit during the quick change of the products.