Русский English

Тестрон

Стационарные рентгеновские аппараты кабельного типа серии EXTRAVOLT

category: extravolt (cable x-ray)



  Стационарные рентгеновские аппараты кабельного типа серии EXTRAVOLT
 

EXTRAVOLT -160 / P1600 – is one-pole, cable X-ray unit of constant potential which is used in the radioscopy and radiography of plastics, composites, ceramics, rubber, light-alloy castings and similar objects.

This high-stable unit of medium power capacity was developed for the joint use with cermet X-ray tubes of the company Thales Electron Devices (France). This unit is recommended for the use together with X-ray TV-detectors in combined systems of radioscopy and for the high-quality radiography on the X-ray film or reusable phosphorous plates.

Technical characteristics:

Maximum voltage of the tube: 160 kV
Maximum anode current of the tube: 15 mA
Maximum power on the anode of the tube: 1600 W
Depth of radiographic inspection in terms of steel: 46 mm*
Recommended X-ray tube: THX160/1010, THX160/1030
High voltage adjustment range: 10...160 kV with pitch of 0.1 kV
Tube current adjustment range: 0.5...15 mA with pitch of 0.1 mA
Accuracy of output parameters setting: ± 1.0% for amperage; ± 1.5% for voltage
Stability / Repeatability: ±0.1% / ±0.01% at constant temperature
Exposure time (pitch of 0,1 min): 0.1 ... 99,9 minutes or continuously
Length of high-voltage cable: 7 m (standard), up to 100 m (by request)
Flow meter of cooling liquid as a set of cooling system

Voltage: 120V…240V   50/60Hz
Working cycle: 100% 24 hours a day at the temperature of up to 40º С
Working temperature:
-20ºС…40ºС (antifreeze-air cooling)
+2ºС…75ºС (antifreeze-water cooling)
Humidity: up to 90% without moisture condensation
Storage conditions: -25ºС…75ºС, humidity up to 95% without condensation
Maximum power consumption: 2.5 kW
Overall dimensions of generator: 980x350x455 mm
Generator weight: 120kg

* The radiographic inspection depth in terms of steel is given for following test conditions:
FOSFOMATIC-35, distance 700mm, 160kV, 1600W, 1st class of sensitivity as per GOST 7512-82.
At the operation in the mode of high dose sensitivity the radiographic inspection of big-thickness steels is possible.

Nomographic chart for iron (Fe)
Distance to the object 700mm
Film class KODAK AA400, FOMA R7, AGFA D7
Lead shield 0,02 mm
Radiographic inspection until the achievement of density 2.0D.

Nomographic chart for iron (Fe)
Distance to the object 700мм
FOSFOMATIC-35 (Flex HR)
Lead shield 0,02 mm
Radiographic inspection as per 1st class of sensitivity in accordance with GOST 7512-82

Data could be changed without notification


Block-diagram of the unit EXTRAVOLT-160.

References to the additional information:
Specification on EXTRAVOLT -160 in PDF
Sanitary and epidemiological conclusion on the unit EXTRAVOLT -160
Cermet tubes, produced by Thales Electron Devices
Description of the unit EXTRAVOLT -160
Criteria for selection of stationary X-ray units

On the pictures:
Экспозиция мА х мин – Exposure mA x min
Радиационная толщина мм – Radiation thickness, mm

Силовой блок – Power unit
Высоковольтный генератор – high-voltage generator
Рентгеновская трубка – X-ray tube
Блок управления – Control unit
Датчик протокаflow meter
Высоковольтный кабель – High-voltage cable
Низковольтный кабель - Low-voltage cable
Водяной шланг – Water hose